Brand Name :RAYSEN
Model Number :6.0/6.5/7.0/7.5/8.0/8.5/9.0
Certification :CE and ISO 13485
Place of Origin :Tianjin,China
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :20200 ctns
Delivery Time :7 Days Deliver
Packaging Details :1pair/bag,50pair/box,500pair/carton
Product :Powder-free Latex Surgical Gloves offer strength and durability-the ideal glove for all general surgical procedures
Packing :1pair/pouch,50pair/box,500pair/carton
Loading :420 cartons into 20ft container
Application :Medical surgery and examination
Certificate :CE and ISO 13485
Name :Disposable Sterile Gloves
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Powder-free Latex Surgical Gloves offer strength and durability-the ideal glove for all general surgical procedures

When strength and dexterity are of the utmost importance, our allergy-free Powder free Nitrile Gloves are the ideal choice. From food handling to engineering, these versatile gloves are sure to suit the task at hand.

Features:
· Latex free
· Micro textured
· Dual approved for medical and industrial use
· Excellent barrier protection AQL 1.5
· Textured finger tips
· Moulds to shape of hand can be worn under working gloves
· Low chemical contact use
Applications:
Clinical tasks, Laboratories, Food processing, Food handling, Automotive and Engineering


Date Sheet

DescriptionSize

Weight
(g/pcs)

Length
(mm)

Width of palm
(mm)

Thickness (mm)Inner boxOuter box
Finger tipPalmCuff

Size
(mm)

Weight
(g/pc)

Size
(mm)

weight
(g/pc)

Latex Surgical
gloves

67±0.3265-27577±50.20±0.020.165±0.020.14±0.02240*130*190150670*255*400800
6.57.5±0.3265-27583±50.20±0.020.165±0.020.14±0.02
78±0.3270-27589±50.20±0.020.165±0.020.14±0.02
7.58.5±0.3270-27595±50.20±0.020.165±0.020.14±0.02
89.5±0.3270-275102±60.20±0.020.165±0.020.14±0.02
8.510.5±0.3280-285108±60.20±0.020.165±0.020.14±0.02
911±0.3280-285114±60.20±0.020.165±0.020.14±0.02
Description

Tensile strength
(Mpa)

Elongation at break
(%)

Aging experimental
conditions

AQLPowder content

Protein content
(ug/dm2)

Before agingAgingBefore agingagingPin hole test

Powdered gloves
(mg/dm2)

Latex Surgical
gloves

2418≥750≥560(70±2)°C×(166±2)h1.5≤120≤200


Intended applications:
Surgical Rubber Gloves –Sterile – Powder free are classified as Class IIa Medical Device as per rule 6 of Annex IX as per MDD/93/42/EEC as amended.These are intended for use by an operating personnel or healthcare workers for following purpose:

  1. To reduce the risk of contamination of health-care workers hands with blood and other body fluids

  2. To reduce the risk of germ dissemination to the environment and of transmission from the health-care worker to the patient and vice versa. As well as from one patient to another.

  3. To reduce the cause of postoperative adhesions, granulomas, delayed wound healing, increased risk of infection and occupational asthma.

  4. Low protein level reduces the cause for latex allergy
    In Laboratory/Pharma manufacturing sector where powder may affect the quality of the product especially in clean rooms, Powder Free Gloves are commonly used.


Raysen Surgical Glove is defined by its high level of comfortability and flexibility. Made with natural rubber latex, its feel and fit allows surgeons to perform to the best of their ability. Recommended for use in day surgeries, dental practices, primary care and veterinary practices.


Contra indications:Latex Surgical gloves are manufactured from NATURAL RUBBER LATEX
CAUTION!
“This product contains natural rubber latex which may cause allergic reaction to some individuals. If
any allergic reation is observed discontinue the use and consult aphysician”
Instructions for use

  1. Each pouch contains one pair separate gloves for left and right hand.

  2. Size No is marked for Selection of gloves of appropriate size.

  3. Do not use the sterilized gloves if package is opened or damaged. Do not re-sterilize damaged or opened pouches.

  4. Must see the date of Manufacturing and expiry date, lot/Batch No. Sterilization Date and Manufacturers address.

  5. Must see the product specification standard reference ( ASTM/EN Standard ) and AQL Level.

  6. Use micro roughened glove for added instrument grip

  7. Limit “Touch Contamination”with soiled gloves

  8. Do not store gloves exposed to direct sunlight, fluorescent lighting or under high Humidity areas and protect from Ozone atmosphere.

  9. Store gloves under cool dry place where temperature does not rise above 35 degree centigrade

  10. The device is for single use only

  11. Disposal after use as per local, state, national regulatory rules shelf life (Use before date) The shelf life of the gloves is 3 years from the date of manufacture.













































Inquiry Cart 0